Browse all practice questions for the North Carolina ElectriCities Intermediate Lineworker Practice Exam. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Amp Up Your Skills for 2026: North Carolina ElectriCities Lineworker Exam Adventure! course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • Raising a secondary with rope blocks requires a rope block attached to a what?
  • What hazard is most likely if the transformer secondary is not properly isolated to prevent backfeed?
  • The mechanical advantage of a block and tackle is determined by what?
  • Why is a ground-fault circuit interrupter (GFCI) not typically used on high-voltage distribution work?
  • In general, are workers safe if they remain below the top of a transformer?
  • What is the first part of any rigging job?
  • What device is used to increase or decrease voltage?
  • In a typical distribution system, how is voltage supplied?
  • Can capacitors store an electrical charge even when they are disconnected from a power source?
  • Why is temporary grounding used during switching operations on a de-energized circuit?
  • What are the major components of a transmission and distribution system?
  • Describe the difference between delta and wye transformer connections, including the presence of a neutral and phase shift.
  • Which of the following is NOT part of the crossarm changeout demonstration?
  • What combination is essential for safe pole-work involving potential falls?
  • Which term describes the network that ties all equipment grounding in a substation to earth?
  • What is the correct procedure for working a switch with a hot-stick from a safe distance?
  • What is the next action after the old crossarm is replaced?
  • Which component's wire is specifically removed in the final transformer removal step to break the grounding path?
  • What is the purpose of a job briefing before starting a line crew task?
  • Which elements should be included in a post-job debrief to improve safety?
  • Which component is used to carry electrical power along the transmission network?
  • Typically, power transformers have a component that comes in at least two different sizes. Which component is this?
  • Which of the following is not typically used in a switchyard?
  • What is the proper response if a coworker is not following safe energized-work procedures?
  • In NFPA 70E terms, what is used to determine the level of PPE required for a task?
  • What does an open circuit breaker do to a circuit?
  • If a structure shows signs of rotting or corrosion, it may not be possible to rig a job safely from the structure.
  • Which of the following statements is correct regarding eye and face protection during arc-flash events?
  • What is the purpose of a temporary grounding circuit and how is it installed?
  • What is the primary purpose of using a tag line when handling transformers?
  • The temporary crossarm was installed close to the old crossarm to minimize movement distance.
  • What does the service drop deliver to the customer?
  • How should PPE gloves be stored and inspected after use?
  • Secondary conductors can be attached using a wedge clamp on the neutral.
  • If two slings lift a load and the legs form a wider angle with vertical, the load in each sling will do what?
  • Temporary crossarms help stabilize permanent crossarms during changeout.
  • Which safety instruction is correct before working on a capacitor?
  • What is a protective device that can open an energized line and is often used to connect a lateral to a feeder?
  • What is the role of a ground watcher during switching operations?
  • Elasticity is defined as the ability of a solid to resist which of the following?
  • Which term describes a scenario where two separate feeders supply electricity to critical customers?
  • Material handling bucket trucks use a chart for the boom and what load rating?
  • Which action is essential when working near exposed energized parts?
  • In a ring bus switchyard, a fault on the bus will result in the entire system being de-energized.
  • In switching operations, which side of a line is typically opened first to de-energize a circuit, and why?
  • Which of the following is not a reason for providing power routing alternatives in a switchyard?
  • During high voltage surges, what provides a way of redirecting excess current to the ground?
  • Are all of the equipment and structures in a substation connected to a grounding grid?
  • Which description best defines the required controls for hot work during line maintenance?
  • Which action helps prevent crossarm misalignment when moving the outside phases?
  • In a distribution transformer, the voltage on the primary winding is generally what relative to the secondary?
  • What is a primary communication requirement for a ground watcher during switching operations?
  • During rigging, increasing the angle of the sling legs away from vertical causes the force in each sling to do what?
  • Setting the gin pole height correctly helps prevent which condition during transformer replacement?
  • Is the voltage applied to the primary winding of a distribution transformer usually higher than the voltage induced in the secondary winding?
  • What is a hot-stick?
  • Why is it important to verify voltage on both sides of a switch or disconnect after opening?
  • When the angle between sling legs and the vertical grows, the tension in each sling does what?
  • A sectionalizer can interrupt the flow of electricity through an energized distribution line.
  • Doughnut-shaped transformers are often found around the bushings of circuit breakers and power transformers. What type are these transformers?
  • What happens if a fault occurs on a feeder?
  • A series connection between primary and secondary windings of a voltage regulator causes the primary to act as part of the secondary winding.
  • What should be included in a post-job debrief?
  • CCVT stands for coupling capacitor voltage transformer.
  • Which device is typically donut-shaped and located around the bushings to measure current?
  • If the sling angle from vertical increases, the forces in the individual sling legs do what?
  • When a load is lifted by multiple slings and the angle from vertical is larger, the tension per sling does what?
  • How is arc-flash boundary determined, and what factors influence it?
  • Which layout uses two separate feeders to supply electricity to critical customers?
  • How should transformers be treated during de-energizing and decommissioning work?
  • MAD is used to determine safe clearance from energized equipment based on which factors?
  • What device looks like a power transformer, except that its bushings are connected only with the source circuit?
  • With two slings sharing a single load, increasing the angle from vertical causes the load on each sling to do what?
  • Which transformer connection provides a neutral and line-to-neutral voltage?
  • When can a handline be used?
  • What is the process of sectionalizing?
  • How does a typical distribution transformer function?
  • Which set of precautions should be followed when approaching arc-flash hazards in a switchyard during maintenance?
  • What is a short circuit and how might you identify one during fault finding?
  • In a regulator, what happens to regulated voltage?
  • Which voltage level is referred to as the voltage delivered to customers in distribution?
  • The final task for removing a transformer requires the lineworker to do what?
  • Which protective device can interrupt current flow through a distribution line?
  • Does a line trap act as a filter to prevent incoming communication signals from passing through a substation?
  • Define a recloser and explain its role in outage restoration.
  • In a switchyard, the common conductors to which circuits are connected are called?
  • Which statement best describes the distinction between primary and secondary distribution in a typical electric utility system?
  • Which statement about stress types in structures is true?
  • Line traps in substations are used to filter and prevent incoming communication signals from passing through the substation. True or False?
  • When the sling angle relative to vertical increases, the load per sling does what?
  • When voltage increases in an AC circuit, what does a connected capacitor do?
  • If two slings share a load and you increase the angle, the load in each sling does what?
  • What is the standard set of hand signals used by ground crews to communicate with the operator?
  • Which type of stress results from a force that pulls on an object?
  • True or False: A capacitor increases the overall efficiency of a distribution system.
  • During fault finding, what would indicate backfeed after opening a switch?
  • With equal load distribution between two slings, widening the angle from vertical results in the force in each sling doing what?
  • In a duplicate supply layout, the customer is supplied with electricity from two separate service drops connected to individual feeders.
  • Substation equipment is protected from excessive current during faults by utilizing what?
  • What is a sectionalizer and how does it differ from a recloser?
  • What is the first step described for rigging work in the material?
  • A transformer improves the overall efficiency of a distribution system by increasing usable power.
  • When verifying zero energy, who may be required to re-test in some procedures?
  • Which type of disconnect is specifically hazardous to open when it carries load current?
  • Moving the two outside phases in sync keeps the crossarm from becoming what?
  • Holding a load steady with two slings, increasing the angle from vertical causes the per-sling load to do what?
  • What is the standard method for maintaining three points of contact when climbing a pole?
  • A block and tackle rigged to the secondary line primarily provides which of the following to the line?
  • As your sling configuration moves away from vertical, the per-sling load tends to do what?
  • Which statement best describes pad-mounted transformers?
  • Which of the following is typically not associated with power transformers: Cooling Equipment, Sealing Equipment, SF6, or Changing Voltage?
  • What is the primary purpose of a face shield or hood in arc-flash PPE?
  • Raising conductors requires continuous coordination between crew members.
  • What is the purpose of a proper grounding system at service equipment, and how is it typically achieved?
  • What is the primary hazard addressed by MAD?
  • The ability of any solid material to resist stress is a measure of the material's what?
  • What is NFPA 70E Hazard Risk Category (HRC) and how does it influence PPE requirements?
  • In a wye transformer connection, what is the role of the neutral?
  • More than one type of stress may be present in a structure at the same time.
  • Are the two main components of a switchyard switches and buses?
  • What is the first step in the crossarm changeout demonstration?
  • What is the maximum safe stress load that a structure is built to withstand called?
  • What is the primary function of a switchyard?
  • One hot hoist was used to move all three conductors because only one conductor can be worked on at a pole. True or false?
  • What is the difference between ACSR and EHS conductors?
  • What is the purpose of maintaining a designated safe working distance during switching operations?
  • If a fault occurs on a lateral, what can a recloser do to allow a fuse to blow?
  • A capstan was used because it allowed the operator clearance from directly under the transformer.
  • How does a typical voltage regulator operate?
  • Which statement best describes the purpose of completing permit procedures before work in a substation?
  • What should you inspect on a climbing belt and lanyard before use?
  • How should you respond to a suspected arc-trace or burnt smell from equipment?
  • When slings are used at an angle from vertical, what happens to the load on each sling?
  • What should be done if a coworker’s failure to follow safe energized-work procedures is observed?
  • Which device is used to regulate reactive power and can resemble a transformer in appearance, but is connected primarily to the source circuit?
  • During a fault on a feeder, which device opens and then recloses the line?
  • The circuits in a switchyard are connected to common conductors called what?
  • What does the acronym CCVT stand for in the context of substation communications?
  • What device is used to reclose after a fault on a lateral?
  • Which type of stress cannot be produced by mechanical forces on a structure?
  • Where are donut-shaped current transformers typically located?
  • Do switchyards typically contain power transformers?
  • When working underneath energized conductors, what should always be observed?
  • What steps ensure safe recovery and re-energization after completing a repair?
  • Which of the following conditions during a pre-job weather check would indicate work should be halted?
  • Which statement best describes the effect of sectionalizing on outages?
  • What is the purpose of a fall-arrest harness in linework?
  • During transformer replacement, why must the gin pole height be carefully set?
  • During de-energizing work, what is a common requirement to prevent re-energization?
  • Gin pole is designed to provide a lifting point away from a utility pole.
  • What constitutes hot work in line maintenance and what controls are typically required?
  • Current flow to ground in a substation is dissipated to the earth through what?
  • Which type of stress can NOT be produced by mechanical forces on a structure?
  • Which statement about circuit breakers is true?
  • Are circuits in a substation electrically connected by conductors called buses?
  • Which hand signal is used to indicate 'incoming' to the operator?
  • Which component is primarily responsible for the voltage change from primary to secondary in a distribution transformer?
  • A secondary disconnected from a transformer should be what to ensure no backfeed?
  • What hazards are associated with working near high-voltage transmission lines on a pole?
  • What should personnel do before working on a capacitor?
  • What is the difference between a pole-mounted transformer and a pad-mounted transformer in terms of accessibility and safety?
  • What hazards are associated with working near high-voltage transmission lines on a pole, and how should they be addressed?
  • Which statement best describes the purpose and installation of a temporary grounding circuit during switching?
  • What is the recommended practice for pole replacement safety?
  • What is the purpose of performing a pre-job weather check, and what factors are considered?
  • What is the primary purpose of using a tag line during transformer handling?
  • What is the purpose of a dead-end anchor or pole when working at height?
  • Why is a non-conductive rope preferred for use around energized lines?
  • Why is ongoing safety training and a strong safety culture essential for lineworkers?
  • How should insulated rubber gloves be tested prior to use?
  • What is the primary purpose of arc-flash PPE, and how is it selected for a task?
  • Which device is used to compensate reactive power in a substation and can resemble a transformer in appearance?
  • In a regulator, what happens to unregulated voltage?
  • In a ring bus switchyard arrangement, is all power cut off when there is a fault on the bus?
  • If part of a circuit in a substation needs to be isolated for maintenance, is the entire substation generally deenergized?
  • What is the purpose of cover-up around exposed energized parts, and where is it required?
  • Tensile stress is produced by which kind of force?
  • Which action minimizes movement distance during crossarm changeout?
  • Circuits in a substation are electrically connected by conductors known as what?
  • The types of switches used in switchyards are circuit breakers and what?
  • Which of the following is NOT an element that most distribution transformers have in common?
  • Which statement accurately describes arc-flash PPE components typically included in an arc-flash ensemble?
  • What is the function of a remotely operated switch in a distribution network?
  • Like substations, do switchyards usually contain protective, monitoring, and communication equipment?
  • What is the primary purpose of lockout/tagout devices?
  • What is the purpose of temporary crossarms in the changeout process?
  • What device steps down transmission voltage to distribution voltage?
  • What action follows transfer back in the crossarm changeout sequence?
  • Serious injury can result from opening what type of disconnect that is energized with load current?
  • What type of voltage is applied to and tapped off of a voltage regulator?
  • New rope has a lower safe working load than used rope.
  • What is the function of a voltage regulator?
  • How do weather conditions affect linework safety?
  • Distribution transformers can be buried underground or mounted overhead on utility poles.
  • What is the function of insulation covers or sleeves on feeders and switches?
  • Which equipment is not typically part of a switchyard?
  • After changing a transformer, what must be done before energizing the customer?
  • What is primary distribution voltage?
  • Why is eye and face protection critical during arc-flash events?
  • Which sequence correctly lists the five basic steps of a formal lockout/tagout procedure before working on equipment?
  • As the angle between the sling legs and the vertical increases, the force in each sling does what?
  • In a typical distribution system, what voltage is supplied to a customer?
  • Which steps should you take to verify a circuit is de-energized before work begins?
  • In lifting operations, if the sling angle from vertical is increased, the load carried by each sling will do what?
  • How should you handle live-line tools that may be contaminated with oil or hydraulic fluid?
  • If a tool or glove becomes damaged during an operation, what should be done?
  • Which statement about arc-flash boundary calculations is NOT a factor in the calculations themselves?
  • Which statement describes why de-energizing and grounding is performed before maintenance?
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy